Vikram Aviation Pvt Ltd operates an NABL-accredited testing and calibration laboratory (ISO/IEC 17025:2017) in New Delhi, near IGI Airport.
Calibration is a separate service from the company's aircraft repair and maintenance work. The laboratory calibrates aircraft instruments, tools, instruments and GSE items for aviation and non-aviation customers, within its approved calibration scope.
Vikram Aviation's DGCA CAR-145 approval includes category C-13: Calibration/overhaul of aircraft instruments.
Calibration of GSE across mechanical, electrical, thermal, electro-mechanical, dimensional disciplines.
Here, GSE (ground support equipment) means the tools, gauges and instruments listed in the calibration scope, such as torque wrenches, pressure gauges and multimeters. It does not mean ground-support vehicles or powered units.
The NABL-accredited calibration scope covers three disciplines: Electro-Technical, Mechanical and Thermal. The areas in each are listed below; instruments and ranges are in the NABL scope table.
Photographs from the laboratory show its equipment and work areas. They do not define the accredited scope: only the items in the NABL scope table are NABL-accredited.
The certificate of accreditation is issued by the National Accreditation Board for Testing and Calibration Laboratories (NABL) under ISO/IEC 17025:2017, “General Requirements for the Competence of Testing & Calibration Laboratories”, in the field of calibration.
A summary of the scope of accreditation. Electro-technical, pressure, humidity and temperature calibration are also listed for site facility. Measurement methods and calibration and measurement capability (CMC) for each entry are given in the full NABL Scope document.
Scope: AC current 100 µA to 10 A (50 Hz to 1 kHz) and up to 1000 A at 50 Hz; AC voltage 10 mV to 750 V (50 Hz to 1 kHz)
Scope: DC current 100 µA to 1000 A; DC voltage 1 mV to 1000 V
Scope: Resistance 1 Ω to 1000 GΩ; capacitance 100 pF to 100 µF
Scope: 50 Hz, 60 V to 300 V, 0.5 A to 5 A
Scope: −200 °C to 1800 °C, depending on type
Scope: Frequency 40 Hz to 1 kHz; time interval 1 s to 86400 s
Scope: AC current 100 µA to 10 A (50 Hz to 1 kHz) and up to 1000 A at 50 Hz; AC voltage 10 mV to 750 V; DC current 100 µA to 1000 A; DC voltage 1 mV to 1000 V; resistance 1 Ω to 1000 GΩ; capacitance 100 pF to 100 µF; temperature simulation −200 °C to 1800 °C, depending on type; frequency 40 Hz to 1 kHz; time interval 1 s to 86400 s
Scope: 20 rpm to 50000 rpm
Scope: 94 dB and 114 dB
Scope: Linear measurements up to 300 mm; angle 0° to 360°
Scope: 1 N to 1000 N
Scope: −0.9 bar to 700 bar
Scope: Hydraulic 0 to 700 bar; pneumatic 0 to 30 bar; manometer and differential pressure 0 to 1000 mbar; vacuum −0.9 bar to 0
Scope: 2 Nm to 2000 Nm
Scope: 10 %rh to 95 %rh @ 25 °C; 10 °C to 50 °C @ 50 %rh
Scope: 10 %rh to 95 %rh @ 25 °C
Scope: −30 °C to 1200 °C
Scope: Multi-position chamber, bath and room calibration −30 °C to 250 °C; indicators and sensors −30 °C to 1200 °C, depending on the item
Only the items in the NABL-accredited scope above are NABL-accredited. Other confirmed calibration services, such as electro-mechanical calibration and instruments listed only under DGCA, are carried out outside the NABL accreditation. When you enquire, ask whether your item is covered by the NABL scope.